1. Finance program for any type of air conditioner. Hotels provide independently air conditioners for each room, customers often put them to operate at temperatures not ever fade. We phase 230 V AC at PH and N the corresponding terminal board us. Cut the sensor on the thermostat of the air conditioner and join in our terminal board. The two ends of the sensor also remain in the terminal of our own. We place our sensor in the same place that the air conditioner and space. The program will diagnose cooling or heating. Up to 23 degrees the air conditioner operates with the setting of the client. If the cooling is requested below or above it stops at 23. This temperature can be varied depending on the desire of hotelier.
2. Electronic thermostat for floor water FAN COILS F94DF. In different molds. Fyrogeni type, type MIDEA, type AIR WELL, type SABIANA, NEOKLIMA, LBC HEAT PUMPS. Everything for fan coils.
3.Electronic thermostat for floor water FAN COILS F94DF. In different molds. Fyrogeni type, type MIDEA, type AIR WELL, type SABIANA, NEOKLIMA, LBC HEAT PUMPS. Everything for fan coils.
4. Digital thermostat FM1 digi. Thermostat for heating, cooling and DHW Combined with digital tables or boilers which produce hot water. Indicator LED. Range from 1 to 63 vathmoi.Tasi 230 V AC 7 A. Thermometer 2 digits. Select HEAT - COOL - WATER - ECONOMY. Timer 48 hr.
5. Electronic Thermostat for FAN COILS water wall. F94F. Voltage 230V AC 7 A. Options HEAT - OFF - COOL, 3 speeds HIGH - MED - LOW. 2 Sensors & space element. 4 Different Mode options for all types. Temperature control element in the hot and cold where we want. Extinguishes itself if forgotten open or air conditioning is turned off.
6.Electronic Thermostat for FAN COILS water wall. F94F. Voltage 230V AC 7 A. Options HEAT - OFF - COOL, 3 speeds HIGH - MED - LOW. 2 Sensors & space element. 4 Different Mode options for all types. Temperature control element in the hot and cold where we want. Extinguishes itself if forgotten open or air conditioning is turned off.
7. Simple electronic control for air conditioner low cost F88TD. Voltage 230V AC 7 A. Delay timer 3 minutes for the compressor. Range 15 to 35 degrees. HEAT-COOL - OFF 10 sec delay for IIGH - MED - LOW at HEAT.
8. Plaques for each air conditioner. F94E, F94A. Program wired or wireless.
9. Program for central air conditioning chillers, cooling fan coils for heating water. Mainboard with all parameters via software. Four sensors, thermometer and desired settings via a wired or wireless controller. Program only for chillers hot water. Main board and controller. Parameters according to the manufacturer. Four sensors for DHW production to 67 degrees without the use of resistors.
10. Dual Program software. This program is a real breakthrough because the construction of a special recovery chiller we produce with water cooling or heating. This produces free hot water 56 degrees. The operation is controlled by sensors 6. Since the controller can select HEAT + ZNX, COOL + ZNX, or just DHW It should be noted that 56 degrees DHW not achieved by any internationally factory only using resistors. In our building there is no resistance. Also go every 7 days the temperature at 70 degrees to combat legionella.
11. Digital panel for boilers. Table for simple table for boilers and boilers produce inside and warm water. Voltage 230 V AC 7 A. A transducer. Adjustable thermostat water. Preset thermostat circulator two levels from 45 to 40, 65 to 60. Safety thermostat with automatic reset. Frost protection for the boiler. Automatic thermostat inactivity. Movement pump every 10 days for 15 sec. Automatic reset. Digital Thermometer 2 digits. Indicator LED Burner, Circulator, overheating. Fault sensor.
12.Plaques for each air conditioner. F94E, F94A. Program wired or wireless. F94Fdigi Digital thermostat for hidden FAN COILS with wireless remote control liquid crystal.
13. Program for central air conditioning chillers, cooling fan coils for heating water. Mainboard with all parameters via software. Four sensors, thermometer and desired settings via a wired or wireless controller. Program only for chillers hot water. Main board and controller. Parameters according to the manufacturer. Four sensors for DHW production to 67 degrees without the use of resistors.
14. Plaque delay timer. Supply voltage 230 V AC to double clamp the board. Relay 7 A 230V AC free in the triple clamp. In the middle position of the triple terminals we tend to want to control. Delay stop in place after we exit delay off. In place Delay start delay after power on. The time is set by the trimmer and min 12 sec, max 3 min.
15. Dual Program software. This program is a real breakthrough because the construction of a special recovery chiller we produce with water cooling or heating. This produces free hot water 56 degrees. The operation is controlled by sensors 6. Since the controller can select HEAT + ZNX, COOL + ZNX, or just DHW It should be noted that 56 degrees DHW not achieved by any internationally factory only using resistors. In our building there is no resistance. Also go every 7 days the temperature at 70 degrees to combat legionella.
16. Special controller for controlling humidity - temperature No1. With this control is the relative humidity of the space and each 9 sec algorythmo sends to the central plate of the cooler leading him to produce such water temperature not to liquefy the ground and accelerates very good cooling. Including room thermostat. Special controller for controlling humidity - temperature No2. Checking relative humidity for up to 8 rooms and decide whether the chiller will lead the zone valves to operate the fan coils or underfloor system. The high-tech humidity sensor with the thermostat set, perform regular air dry the floor.
17. Digital thermostat for FM2 digi FAN COILS NEROU. Thermostatisme choice of three speeds HIGH - MED - LOW.
18. Electronic thermostat for water FAN COILS floor. F94DF. In different molds. Fyrogeni type, type MIDEA, type AIR WELL, type SABIANA, NEOKLIMA, LBC HEAT PUMPS. Everything for fan coils.
19. Finance program for any type of air conditioner. At the hotels are independently air conditioners for each room, customers often put them to work in thermokrasiespou not ever fade. We phase 230 V AC at PH and N the corresponding terminal board us. Cut the sensor on the thermostat of the air conditioner and join in our terminal board. The two ends of the sensor also remain in the terminal of our own. We place our sensor in the same place that the air conditioner and space. The program will diagnose cooling or heating. Up to 23 degrees the air conditioner operates with the setting of the client. If the cooling is requested below or above it stops at 23. This temperature can be varied depending on the desire of hotelier.
20. UNIVERSAL REMOTE CONTROL 4000 IN 1 Remote for replacement of damaged air conditioners.
21. Electronic Thermostat for FAN COILS water wall. F94F. Voltage 230V AC 7 A. Options HEAT - OFF - COOL 3 speeds HIGH - MED - LOW. 2 Sensors & space element. 4 Different Mode options for all types. Temperature control element in the hot and cold where we want. Extinguishes itself if forgotten open or air conditioning is turned off.
22. Electronic thermostat F1, F4. Simple electronic thermostat 230V AC 7 A. From 6 to 26 degrees. Indicator LED O first simple electronic thermostat in Greece and probably in Europe. Taught in technical schools like FASMA
23. Electronic thermostat for water FAN COILS floor. F94DF. Fyrogeni type, type MIDEA, type AIR WELL, type SABIANA, NEOKLIMA, LBC HEAT PUMPS. Everything for fan coils.
24. Dual Analog thermostat. Heat-Cool. Output 0-10 V DC. Temperature range Heat 30-60 degrees Celsius. Temperature range Cool 10-30 degrees Celsius. Suitable for pump inverter.
25. Controller board and any air conditioner. Control Infrared 4000 in 1 codes made in China. PCB and program 1. For air conditioners with fan: Hight-Medium-Low 2. Program for air conditioners with fan inverter 3. Programme for Water fan coils. Construction in Greece with unlimited warranty. Includes thermostat 3 minutes delay for the compressor. Complete thawing, after 20 minutes of operation whenever needed. Check out fan for high pressure, stop the compressor if necessary. Thaw protection. Control sensors. Auto restart on power failure. Ability to change the program on the board. Ability to monitor the operation of a PC. Auto Swing.
26. Controller board and any air conditioner. Control Infrared 4000 in 1 codes made in China. PCB and program 1. For air conditioners with fan: Hight-Medium-Low 2. Program for air conditioners with fan inverter 3. Programme for Water fan coils. Construction in Greece with unlimited warranty. Includes thermostat 3 minutes delay for the compressor. Complete thawing, after 20 minutes of operation whenever needed. Check out fan for high pressure, stop the compressor if necessary. Thaw protection. Control sensors. Auto restart on power failure. Ability to change the program on the board. Ability to monitor the operation of a PC. Auto Swing.
27. Digital Analogue panel for boilers. Oil-Wood. Includes digital thermometer, hydrostatic safety burner pump. Automatic reset, automatic or manual fan speed setting.
28. Digital and Analog Table 3 to 1. For Boilers Oil-Wood-Pellet. Includes choice of operation for burning oil, wood, Pellet. Digital and analog control of all levels. Hydrostatic security. Hydrostatic burner Wood, Pellet. Timer on / off for Pellet. Thermometer 0 to 100 degrees. Automatic reset. Automatic or manual adjustment of air. Check konchlia and silo on fire. Amperometrisi engine Pellet. Automatic fire. Continuous control sensors.
29. New liquid crystal walls controller for FAN COILS water conditioners or central air conditioning, compatible with all previous models.
30. Same as No. 29, a DISPLAY screen 20MM.
31. New wall thermostat for central air conditioner / fan coil Unit. LCD touch screen, backlight blue. Heat Cool Fan. Speed High Med Low. Networking RS485 or Modbus.
32. Single-phase motor speed regulator. Frequency display 0 - 50 Hz Analog input jack 0 - 10 VOLT DC. For mounting an external analog thermostat (such as products No. 24, 25)
33. Single-phase motor speed regulator. Frequency display 0 - 50 Hz Analog input jack 0 - 10 VOLT DC. For mounting an external analog thermostat (such as products No. 24, 25)
34. Digital thermostat for water fan coils with 2 hot / cold sensors and 3 speeds. Temperature adjustment from -50 to +110 degrees Celsius. Delay timer 1min to 10min
35. Full digital panel for oil-gas boilers
36. Full Digital Panel for Pellet-Boiler Boilers with or without Amperocimps Control
37. New Digital wall-floor thermostat. Lcd touch screen black light blue. Suitable for pumps air conditioning and water fan coil. With one or two sensors easy handling, range 5 to 35 degrees. Differential 0.5 to 1 b.Timer On-Off. Sensor calibration. Lock. Synchronous or asynchronous operation Valve-speed. 4 Relay. Dimensions of wall thermostat 88 x 88 mm height 35 mm. Built-in type dimensions 86 x 86 height 15 mm box 63 x 45 height 25 mm. Same dimensions for installation on the floor.
38. New Analogue thermostat for new Fan Coils MIDEA floor-to-wall. Two space-water sensors. Dimensions floor x 86 x 86 mm, mounting hole dimensions 81 x 81 mm. Wall dimensions 88 x 88 mm height 35 mm.